CASTING closed systems open systems pre-set stones
Density: 12,90 g/cm3
Hardness (as cast): 120 HV
Hardness (after annealing): 115 HV
DIRECTIONS FOR SUGGESTED USE
Melting temperature: 890 °C
Casting temperature:
100 °C over its melting temperature to cast with centrifugal machines.
120 °C over its melting temperature to cast in vacuum machines with controlled atmosphere.
140 °C over its melting temperature to cast in outdoor cylinders with vacuum.
Cylinders temperature: from 550 °C to 650 °C depending on the machine and
objects dimensions.
Cooling casted objects: in water after 10 minutes.
Annealing: 650 °C for 20 minutes followed by a quick cooling in hot
water (40 °C min.)